1 .BY USING AUTOMATIC STAMPING MAKING A PERFECT DIAMETER WITH HIGH RETAINING
POWER.
2. USUALLY ASSEMBLE WITH HEX BOLT, EYE BOLT OR HOOK BOLT.
3. HIGH DUTY APPLICATION.
TAM ANCHOR(PLATING THICKNESS 3一5 um)
CODE NO | SIZE | THERAD mm | DIAMETER ANCHOR mm | ANCHOR LENGTH mm | DIAMETER HOLE ∅mm | MINIMAL EMBEDMENT | ANCHOR WELGHT KGS/1000PCS | PACKING BOX/CARTON |
TA-06 | M6×45 | M6 | 10 | 45 | 11 | 48 | 9.5 | 200/2000 |
TA-08 | M8×50 | M8 | 12 | 51 | 13.5 | 54 | 15.6 | 200/1000 |
TA-10 | M10×60 | M10 | 16 | 60 | 17 | 63 | 29.8 | 150/750 |
TA-12 | M12×73 | M12 | 18 | 73 | 19 | 76 | 45.7 | 100/500 |
PULL OUT LOAD SPECIFICATION
SIZE mm | TORQUE WRENCH Nm | TENSILE STRENGTH (Mpa) | SHEAR STRENGTH (Mpa) | SAFETY PULL OUT LOAD KGS |
M6 | M6×45 | 610 | 372 | 750 |
M8 | M8×50 | 586 | 375 | 1100 |
M10 | M10×60 | 591 | 379 | 1550 |
M12 | M12×73 | 578 | 362 | 2300 |
INSTALLATION OF PULL OUT LOAD
1. 5 pcs Anchor for Testing.
2. Drilla hole.
3. Measure hole depth.
4. Clean the hole, prepare Anchor.
5. Put the Anchor in the hole by Hammering.
6. Using Torque Wrench to fast the Anchor(Nm).
7. Installed Pull out Load Machine.
8. Start to Pull out the Anchor.
9. See the Pull out Load Strength when the concrete is Broken.
1 0.The concrete will Broken when the Anchor is Pull out.
FINAL TEST REPORT OF PULL OUT LOAD
SIZE mm | PULL OUT LOAD KGS RESULT |
M6 | 1100 |
M8 | 1850 |
M10 | 2550 |
M12 | 3800 |