1.HIGH DUTY APPLICATION, ANCHOR ASSEMBLED WITH BOLT, PIPE, WASHER, SPRING WASHER AND NUT.
2.BYTURNING THE NUT IT WILL CREAT GREAT EXPAND INTO CONCRETE.
3.SPRING WASHER USE TO HOLD VIBRATION.
4.AVAILABLE IN STAINLESS STEEL.

BOLT ANCHOR ( PLATING THICKNESS 3-5 um ) |
CODENO | SIZE | THREAD | DIAMETER SLEEVE Фmm | SLEEVE LENGTH mm | DIAMETER HOLE Фmm | ANCHOR WEIGHT KGS/1000 | PACKING BOX/CTN |
BA-650 | M6(1/4-20WT)X50 | M6(1/4) | 9.5 | 30 | 9.5 | 21.04 | 100/1000 |
BA-865 | M8(5/16-18WT)X65 | M8(5/16) | 12 | 35 | 12 | 48.24 | 100/500 |
BA-870 | M8(5/16-18WT)X70 | M8(5/16) | 12 | 35 | 12 | 49.84 | 100/500 |
BA-1070 | M10(3/8-16WT)X70 | M10(3/8) | 14 | 40 | 14.5 | 72.3 | 60/300 |
BA-1080 | M10(3/8-16WT)X80 | M10(3/8) | 14 | 40 | 14.5 | 78.25 | 60/300 |
BA-1012 | M10(3/8-16WT)X120 | M10(3/8) | 14 | 40 | 14.5 | 99.1 | 50/250 |
BA-1210 | M12(1/2-12WT)X100 | M12(1/2) | 17.3 | 50 | 18 | 159.9 | 30/150 |
BA-1215 | M12(1/2-12WT)X150 | M12(1/2) | 17.3 | 50 | 18 | 202.9 | 20/100 |
BA-1610 | M16(5/8-11WT)X100 | M16(5/8) | 21.7 | 50 | 22 | 233.1 | 20/100 |
BA-1610 | M16(5/8-11WT)X150 | M16(5/8) | 21.7 | 60 | 22 | 332.9 | 12/60. |
BA-2016 | M20(3/4-10WT)X160 | M20(3/4) | 25.4 | 80 | 26 | 593.4 | 8/40. |
BA-2016 | M20(3/4-10WT)X200 | M20(3/4) | 25.4 | 80 | 26 | 688.7 | 6/30. |
STAINLESS STEEL IS AVAILABLE |
PULL OUT LOAD SPECIFICATION |
SIZE mm | MATERIAL SIZE Ф mm | TORGUE WRENCH Nm | TENSILE STRENGTH σь (Mpa) | SHEARSTRENGTHτb (Mpa) | SAFETY PULL OUT LOAD KGS |
M6 | 4.32 | 6 | 595 | 376 | 780 |
M8 | 5.13 | 12 | 588 | 381 | 1200 |
M10 | 6.91 | 25 | 579 | 377 | 1400 |
M12 | 8.75 | 45 | 592 | 367 | 2200 |
M16 | 10.56 | 70 | 563 | 363 | 2850 |
M20 | 14.36 | 130 | 544 | 366 | 4300 |
INSTALLATION OF PULL OUT LOAD |
1. 5 pcs Anchor for Testing. 2. Drill a hole. 3. Measure hole depth. 4. Clean the hole, prepare Anchor. 5. Put the Anchor in the hole by Hammering. 6. Using Torque Wrench to fast the Anchor ( Nm ). 7. Installed Pull out Load Machine. 8. Start to Pull out the Anchor. 9. See the Pull out Load Strength when the concrete is Broken. 10.The concrete will Broken when the Anchor is Pull out. |

FINAL TEST REPORT OF PULL OUT LOAD |
SIZE mm | MATERIA LSIZE Ф mm | PULL OUT LOAD KGS RESULT |
M6 | 5.13 | 1500 |
M8 | 6.85 | 1700 |
M10 | 8.75 | 3200 |
M12 | 10.56 | 5200 |
M16 | 14.36 | 7200 |
M20 | 17.97 | 9200 |