SLEEVE ANCHOR ROUND HOLE TYPE ( PLATING THICKNESS 3-5 um )
TYPE RH | CODE NO | SIZE | THREAD | MAXIMAL FAST THICKNESS (mm) | DIAMETER SLEEVE Фmm | DIAMETER HOLE Фmm | MIN HOLE DEPTH mm | ANCHOR WEIGHT KGS/1000PCS | PACKING BOX/CTN | TYPE |
HB
HBP
HKB
HKBP
EB
EBP
LB
LBP
HKBNN
HKBNNP
HKBF
HKBF
EBNN
EBNNP | HBRH-68-45 | M6x45 | M6 | 3 | 8 | 8 | 43 | 17.46 | 100/1000 | FHIH FHPH FHIHP FHPHP |
HBRH-68-60 | M6x60 | M6 | 13 | 8 | 8 | 43 | 22.40 | 100/1000 |
HBRH-69-45 | M6x45 | M6 | 23 | 9 | 9 | 43 | 19.90 | 100/1000 |
HBRH-69-60 | M6x60 | M6 | 43 | 9 | 9 | 43 | 23.40 | 100/1000 |
HBRH-810-60 | M8x60 | M8 | 60 | 10 | 10 | 55 | 38.90 | 120/600 |
HBRH-810-80 | M8x80 | M8 | 5 | 10 | 10 | 55 | 48.60 | 100/500 |
HBRH-811-60 | M8x60 | M8 | 15 | 11 | 11 | 55 | 39.80 | 120/600 |
HBRH-811-80 | M8x80 | M8 | 30 | 11 | 11 | 55 | 48.70 | 100/500 |
HBRH-1012-70 | M10x70 | M10 | 35 | 12 | 12 | 70 | 66.30 | 70/350 |
HBRH-1012-100 | M10x100 | M10 | 55 | 12 | 12 | 70 | 88.50 | 50/250 |
HBRH-1014-70 | M10x70 | M10 | 75 | 14 | 14 | 70 | 68.70 | 70/350 |
HBRH-1014-100 | M10x100 | M10 | 15 | 14 | 14 | 70 | 90.90 | 50/250 |
HBRH-1216-80 | M12x80 | M12 | 20 | 16 | 16 | 80 | 115.90 | 40/200 |
HBRH-1216-110 | M12x110 | M12 | 36 | 16 | 16 | 80 | 151.20 | 30/150 |
HBRH-1620-110 | M16x110 | M16 | 15 | 20 | 20 | 90 | 291.00 | 15/75 |
PULL OUT LOAD SPECIFICATION |
SIZE mm | MATERIALSIZE Фmm | TORGUE WRENCH Nm | TENSILESTRENGTH σь (Mpa) | SHEAR STRENGTH τb (Mpa) | SAFETYPULL OUT LOAD KGS |
M5 | 4.32 | 6 | 595 | 376 | 680 |
M6 | 5.13 | 12 | 588 | 381 | 850 |
M8 | 6.91 | 25 | 579 | 377 | 1000 |
M10 | 8.75 | 45 | 592 | 367 | 1500 |
M12 | 10.56 | 70 | 563 | 363 | 2200 |
M16 | 14.36 | 130 | 544 | 366 | 3200 |
INSTALLATION OF PULL OUT LOAD |
1. 5 pcs Anchor for Testing. 2. Drill a hole. 3. Measure hole depth. 4. Clean the hole, prepare Anchor. 5. Put the Anchor in the hole by Hammering. 6. Using Torque Wrench to fast the Anchor ( Nm ). 7. Installed Pull out Load Machine. 8. Start to Pull out the Anchor. 9. See the Pull out Load Strength when the concrete is Broken. 10.The concrete will Broken when the Anchor is Pull out. |

FINAL TEST REPORT OF PULL OUT LOAD |
SIZEmm | MATERIAL SIZEФ mm | PULL OUT LOAD KGS RESULT | M5 | 4.32 | 1200 | M6 | 5.13 | 1600 | M8 | 6.85 | 1850 | M10 | 8.75 | 3300 | M12 | 10.56 | 5300 | M16 | 14.36 | 7350 |
|  |